Approved sources
Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.
OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →
INSULATOR,STANDOFF
design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)
397L1 ISOLANTITE MANUFACTURING CO INC (81143)
CONFIRMED
INSULATOR,STANDOFF
design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)
445 BIRNBACH CO INC (71002)
CONFIRMED
INSULATOR,STANDOFF
design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)
564485 STEWART-WARNER CORPORATION (57733)
CONFIRMED
INSULATOR,STANDOFF
design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)
61170 NAVAL SHIP SYSTEMS COMMAND (80064)
CONFIRMED
INSULATOR,STANDOFF
design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)
94G295 ZIERICK MFG CORP (79963)
CONFIRMED
INSULATOR,STANDOFF
design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)
A8514-7 RAYTHEON COMPANY (06845)
CONFIRMED
INSULATOR,STANDOFF
design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)
339D827H24 NORTHROP GRUMMAN SUPPORT SERVICES C (48306)
POSSIBLE
INSULATOR,STANDOFF
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
Historical & informational references
Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.
20979 ALLISON LABORATORIES (96219)
WITHDRAWN
INSULATOR,STANDOFF
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
339D827H24 NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)
WITHDRAWN
INSULATOR,STANDOFF
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
802900-19 SAFRAN POWER USA, LLC (81640)
WITHDRAWN
INSULATOR,STANDOFF
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
A00A029-1 NAVCOM DEFENSE ELECTRONICS, INC. (57057)
WITHDRAWN
INSULATOR,STANDOFF
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
A819 AVIONICS CORP OF AMERICA (00531)
WITHDRAWN
INSULATOR,STANDOFF
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATOR,STANDOFF
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
Substitutes — other stock numbers
Codified interchangeability across stock numbers (FLIS I&S), with the catalogue's order of use where it states one.
OEM source-control number — the OEM’s own reference for this item; the other members are its approved sources per codification. All of this OEM’s references →
INSULATOR,STANDOFF
NSN 5970-00-117-5230
THREAD LENGTH: 0.500 INCHES NOMINAL SCREW THREAD DIAMETER AND LOCATION: 0.138 MOUNTING FACILITY INCHES NOMINAL OVERALL HEIGHT: 1.000 INCHES NOMINAL IDENTIFICATION CODE COLOR: WHITE
397L1 ISOLANTITE MANUFACTURING CO INC
CONFIRMED
INSULATOR,STANDOFF
NSN 5970-00-117-5230
THREAD LENGTH: 0.500 INCHES NOMINAL SCREW THREAD DIAMETER AND LOCATION: 0.138 MOUNTING FACILITY INCHES NOMINAL OVERALL HEIGHT: 1.000 INCHES NOMINAL IDENTIFICATION CODE COLOR: WHITE
445 BIRNBACH CO INC
CONFIRMED
INSULATOR,STANDOFF
NSN 5970-00-117-5230
THREAD LENGTH: 0.500 INCHES NOMINAL SCREW THREAD DIAMETER AND LOCATION: 0.138 MOUNTING FACILITY INCHES NOMINAL OVERALL HEIGHT: 1.000 INCHES NOMINAL IDENTIFICATION CODE COLOR: WHITE
564485 STEWART-WARNER CORPORATION
CONFIRMED
INSULATOR,STANDOFF
NSN 5970-00-117-5230
THREAD LENGTH: 0.500 INCHES NOMINAL SCREW THREAD DIAMETER AND LOCATION: 0.138 MOUNTING FACILITY INCHES NOMINAL OVERALL HEIGHT: 1.000 INCHES NOMINAL IDENTIFICATION CODE COLOR: WHITE
61170 NAVAL SHIP SYSTEMS COMMAND
CONFIRMED
INSULATOR,STANDOFF
NSN 5970-00-117-5230
THREAD LENGTH: 0.500 INCHES NOMINAL SCREW THREAD DIAMETER AND LOCATION: 0.138 MOUNTING FACILITY INCHES NOMINAL OVERALL HEIGHT: 1.000 INCHES NOMINAL IDENTIFICATION CODE COLOR: WHITE
94G295 ZIERICK MFG CORP
CONFIRMED
INSULATOR,STANDOFF
NSN 5970-00-117-5230
THREAD LENGTH: 0.500 INCHES NOMINAL SCREW THREAD DIAMETER AND LOCATION: 0.138 MOUNTING FACILITY INCHES NOMINAL OVERALL HEIGHT: 1.000 INCHES NOMINAL IDENTIFICATION CODE COLOR: WHITE
INSULATOR,STANDOFF
NSN 5970-00-117-5230
THREAD LENGTH: 0.500 INCHES NOMINAL SCREW THREAD DIAMETER AND LOCATION: 0.138 MOUNTING FACILITY INCHES NOMINAL OVERALL HEIGHT: 1.000 INCHES NOMINAL IDENTIFICATION CODE COLOR: WHITE
Stated characteristics
The codification record's own dimensions and material statements — official, and public by nature.
IDENTIFICATION CODE COLORWHITEFLIS characteristics (MRC)
THREAD LENGTH0.500 INCHES NOMINALFLIS characteristics (MRC)
OVERALL HEIGHT1.000 INCHES NOMINALFLIS characteristics (MRC)
THREAD LOCATIONMOUNTING FACILITYFLIS characteristics (MRC)
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S)FLIS characteristics (MRC)
SCREW THREAD QUANTITY PER INCH AND LOCATION32 MOUNTING FACILITYFLIS characteristics (MRC)
SCREW THREAD DIAMETER AND LOCATION0.138 MOUNTING FACILITY INCHES NOMINALFLIS characteristics (MRC)
MATERIALCERAMIC OVERALLFLIS characteristics (MRC)
STYLE DESIGNATORPILLARFLIS characteristics (MRC)
Take the family with you
The whole group as CSV — members, makers, stock numbers and order of use.
Export paused
The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.
Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.
Staying inside the regulation — routes from candidate to approved
Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).
- Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
- Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
- Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
- Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
- FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
- Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.
Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.
Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.