Trail

Consumables & expendables · Spec-Crosswalk

INSULATION SLEEVING,ELECTRICAL

Stock number · one item of supply — the parts codified against it, and the stock numbers it substitutes for

← Search another part, spec or stock number

Purchasable unitnone derived yet
Part number2 approved sources
You are here · Stock number5970-00-740-2971
Specificationnone cited

Approved sources

Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.

BACT63A56-9 THE BOEING COMPANY (81205)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

687-7120-001 ROCKWELL COLLINS, INC. (13499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

687-7120-002 ROCKWELL COLLINS, INC. (13499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

687-7120-004 ROCKWELL COLLINS, INC. (13499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

687-7120-005 ROCKWELL COLLINS, INC. (13499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

687-7120-006 ROCKWELL COLLINS, INC. (13499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

BACJ40DK5A5A THE BOEING COMPANY (81205)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

S2014+18W NORTHROP GRUMMAN SYSTEMS CORPORATION (26512)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

TMS-SCE-375 TE CONNECTIVITY CORPORATION (06090)

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)

065-001756-021 NORTHROP GRUMMAN SYSTEMS CORPORATIO (26916)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

1130389G32 L3HARRIS TECHNOLOGIES, INC. (31550)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11699912-42 ARMY, UNITED STATES DEPARTMENT OF T (19204)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11699912-98 ARMY, UNITED STATES DEPARTMENT OF T (19204)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11830621-154 COMBAT CAPABILITIES DEVELOPMENT (19203)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

119A2290-154 GENERAL DYNAMICS-OTS, INC. (05606)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

170-6513 AMIDATA SAU (369BB)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

224845-907 BAE SYSTEMS INFORMATION AND ELECTRO (81413)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

395086 EATON AEROSPACE, LLC (62983)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

446320-207 RAYTHEON COMPANY (37695)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

44791JP7AS NORTHROP GRUMMAN SUPPORT SERVICES C (48306)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

597532-9-7 HAMILTON SUNDSTRAND CORPORATION (73030)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

94-0054 BAE SYSTEMS INFORMATION & ELECTRONI (19397)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FIT-221 3/8IN WHITE BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

MP-M0013-107 RAYTHEON E-SYSTEMS, INC (33875)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

PENNTUBE V FLEXIBLE 3/8IN WHITE SAINT-GOBAIN PERFORMANCE PLASTICS (09795)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF100 TE CONNECTIVITY (K1010)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF100 TYPE 1 WHITE TE CONNECTIVITY (K1010)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF100TYPE1-0-3751NWH1TE TE CONNECTIVITY (K1010)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF100TYPE1-0375INWHITE TE CONNECTIVITY (K1010)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

ST-221-3/8IN WHITE MANHATTAN/CDT COLE-FLEX (56352)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

124663-003 U S ARMY TANK AUTOMOTIVE COMMAND (19207)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

2296632PC34 NAVAL SEA SYSTEMS COMMAND (53711)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

2296632PC35 NAVAL SEA SYSTEMS COMMAND (53711)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

267M0048P047 RAYTHEON COMPANY (49956)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

7956686-06 LOCKHEED MARTIN CORP (90536)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

816TE0064 FINMECCANICA SPA (A0199)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

FIT221-3-8WHITE BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

FP301-1 3/8 IN WHITE 3M COMPANY (53387)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

RNF-100-123-9 TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

RNF100-3-8TY1WH TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

RNF100-3-8W TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

What defines this item

Specifications and drawings the catalogue records against this number. These are what the parts above are made to — never alternatives to them.

  • AMS-DTL-23053/5 — SAE (AS / AMS) (specification · not yet a document in the graph)
  • AMS3636 — SAE (AS / AMS)
  • M23053/5-107-9 — SAE (AS / AMS) (specification · not yet a document in the graph)
  • M23059/5-107-9 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053 — Military Specifications
  • MIL-I-23053/5 — Military Specifications (specification · not yet a document in the graph)
  • MILI23053/5CL1WHITE — Military Specifications (specification · not yet a document in the graph)
  • MS23053-5-107-9 — Military Standards (MS) (specification · not yet a document in the graph)
  • SAE AS23053/5 — SAE International (AS / AMS) (specification · not yet a document in the graph)
  • SAE-AMS-DTL-23053/5 — SAE International (AS / AMS) (specification · not yet a document in the graph)

Historical & informational references

Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.

10134038 NIMIKKEISTOKESKUS NCB FINLAND (A486G)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

124663 U S ARMY TANK AUTOMOTIVE COMMAND (19207)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

152-3992-00 ROCKWELL COLLINS, INC. (13499)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

344635-7 RAYTHEON COMPANY (49956)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

4000249 L3HARRIS INTERSTATE ELECTRONICS (07421)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

44791JP7AS NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

591-0147-007 THE BOEING COMPANY (94756)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970007402971 E.C.A ETABLISSEMENT (SCY13)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL0812376 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL0839399 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL1388460 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

7230941-P27 LOCKHEED MARTIN CORPORATION (03538)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

829-005-077 NAVCOM DEFENSE ELECTRONICS, INC. (57057)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

FP301-1 3/8 IN WHITE 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

MMS-809-9-T3/8 THE BOEING COMPANY (76301)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

R2479P7 LOCKHEED MARTIN CORPORATION (23991)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100-3/8-WH-SP TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100TYPE1 3/8IN WHITE TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF100 3/8IN WHITE TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

ST0150AB0052CL1 3/8-9 THE BOEING COMPANY (94756)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Y00037-057 BAE SYSTEMS INFORMATION AND ELECTRO (12436)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Substitutes — other stock numbers

Codified interchangeability across stock numbers (FLIS I&S), with the catalogue's order of use where it states one.

M23053/5-107-9 SAE INTERNATIONAL

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-740-2971

TMS-SCE-375 TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-740-2971

Take the family with you

The whole group as CSV — members, makers, stock numbers and order of use.

Export paused

The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.

Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.

Staying inside the regulation — routes from candidate to approved

Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).

  1. Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
  2. Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
  3. Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
  4. Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
  5. FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
  6. Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.

Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.

Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.

Source: DLA Logistics Information Services (FLIS) · cycle 2026-0 · official codification

This crosswalk identifies candidate equivalents with cited evidence. It is not an airworthiness approval. Substitution decisions remain subject to your organisation’s procurement and engineering approval process and the governing maintenance data (AMM/CMM/SRM/CML/OMAT).