Trail

Consumables & expendables · Spec-Crosswalk

INSPECTION PENETRANT KIT

Stock number · one item of supply — the parts codified against it, and the stock numbers it substitutes for

← Search another part, spec or stock number

Purchasable unitnone derived yet
Part numbernone recorded
You are here · Stock number6850-00-826-0981
Specificationnone cited

Approved sources

Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.

D-70 DEVELOPER MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

D-701 DEVELOPER (SEE SUPPL DATA) MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

D-703 DEVELOPER (SEE SUPPL DATA) MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

D-NF, CRACK CHECK DEVELOPER DYNAFLUX, INC. (0CHD7)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

E-59 REMOVER MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

E-59 REMOVER PART G INSPECTION - MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FAULT FINDER CLEANER 1071 CROWN INDUSTRIAL PRODUCTS CO (92381)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FAULT FINDER CLEANER GROUP 1 #1- CROWN INDUSTRIAL PRODUCTS CO (92381)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FAULT FINDER DEVELOPER GROUP 1 - CROWN INDUSTRIAL PRODUCTS CO (92381)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FAULT FINDER PENETRANT GROUP 1 - CROWN INDUSTRIAL PRODUCTS CO (92381)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FLAW-FINDER AG-1-VS PENETRANT AMERICAN GAS & CHEMICAL CO LTD (03530)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FLAW-FINDER AG-DH DEVELOPER AMERICAN GAS & CHEMICAL CO LTD (03530)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FLAW-FINDER AG-RH CLEANER (POST- AMERICAN GAS & CHEMICAL CO LTD (03530)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FLAW-FINDER AG-RH CLEANER (PRE - AMERICAN GAS & CHEMICAL CO LTD (03530)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

P-HF, CRACK CHECK PENETRANT DYNAFLUX, INC. (0CHD7)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

R-501 REMOVER, PART C INSPECTIO- MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKC-NF CLEANER/REMOVER,FORMRLY - ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKC-NF/ZC-7B CLEANER/REMOVR(SEE- ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKD-NF/ZP-9B DEVELOPER, (NEW FO- ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKD-NF/ZP-9B DEVELOPER(NEW-SEE - ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKD-NF/ZP-9B DEVELOPER(OLD-SEE - ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKD-S SPOTCHECK DEVELOPER(SEE S- ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKL-HF/S SPOTCHECK PENETRANT(SE- ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SKL-LO SPOTCHECK PENETRANT(SEE - ILLINOIS TOOL WORKS, INC. (37676)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

VP-30 PENETRANT (SEE SUPPL DATA) MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

VP-31A PENETRANT (SEE SUPPL DAT- MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

VP-31A PENETRANT MCGEAN-ROHCO INC (98733)

POSSIBLE

INSPECTION PENETRANT KIT

codified reference — recorded against this stock number; the catalogue grade is not held

What defines this item

Specifications and drawings the catalogue records against this number. These are what the parts above are made to — never alternatives to them.

  • AMS 2644 — SAE International (AS / AMS) (specification · not yet a document in the graph)
  • AMS 2644 TY2MEC — SAE International (AS / AMS) (specification · not yet a document in the graph)

Historical & informational references

Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.

6850008260981 E.C.A ETABLISSEMENT CENTRAL DES (A00AM)

WITHDRAWN

INSPECTION PENETRANT KIT

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

MIL-I-25135 TY2MEC GENERAL SERVICES ADMINISTRATION (80244)

WITHDRAWN

INSPECTION PENETRANT KIT

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Stated characteristics

The codification record's own dimensions and material statements — official, and public by nature.

COMPONENT QUANTITY9FLIS characteristics (MRC)
PART NAME ASSIGNED BY CONTROLLING AGENCYINSPECTION PENETRANT KITFLIS characteristics (MRC)
SPECIAL FEATURESKIT CONTAINS NINE 7 OZ. AEROSOL CANS; THREE EACH OF PENETRANT, DEVELOPER, AND PENETRANT REMOVERFLIS characteristics (MRC)
NONDEFINITIVE SPEC/STD DATA2 TYPE AND C METHODFLIS characteristics (MRC)
DEPARTURE FROM CITED DOCUMENTAS MODIFIED BY GROUP 1,PENETRANT MA-6,PENETRANT REMOVER MB4,DEVELOPER MC-4FLIS characteristics (MRC)

Take the family with you

The whole group as CSV — members, makers, stock numbers and order of use.

Export paused

The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.

Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.

Staying inside the regulation — routes from candidate to approved

Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).

  1. Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
  2. Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
  3. Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
  4. Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
  5. FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
  6. Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.

Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.

Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.

Source: DLA Logistics Information Services (FLIS) · official codification

This crosswalk identifies candidate equivalents with cited evidence. It is not an airworthiness approval. Substitution decisions remain subject to your organisation’s procurement and engineering approval process and the governing maintenance data (AMM/CMM/SRM/CML/OMAT).