Trail

Consumables & expendables · Spec-Crosswalk

INSULATION SLEEVING,ELECTRICAL

Stock number · one item of supply — the parts codified against it, and the stock numbers it substitutes for

← Search another part, spec or stock number

Purchasable unitnone derived yet
Part number2 approved sources
You are here · Stock number5970-00-050-5659
Specificationnone cited

Approved sources

Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.

GS830L-0W NORTHROP GRUMMAN SYSTEMS CORPORATION (26512)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

PVC-105-5/16-3 BELDEN, INC. (92194)

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)

PVC-105-5/16WHITE BELDEN, INC. (92194)

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)

591-008-049 THE BOEING COMPANY (94756)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FLEXITE HT-105C MARKEL CORP. (03890)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

ITCO 929 PEXCO LLC (12509)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

P-105/5/16 IN-3 MANHATTAN/CDT COLE-FLEX (56352)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

S9562-01-3 HONEYWELL INTERNATIONAL INC. (70210)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

TURBOLEX 105 PRYSMIAN CABLES AND SYSTEMS USA, LL (71124)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

411634-3309 RAYTHEON COMPANY (96214)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

44791AB7A5 NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

44791AB7QS NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

NATVAR 400/461 HIGH VOLTAGE ENGINEERING CORP NATVAR (96904)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

PVC-105-5/16 BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

S9562-0-3 HONEYWELL INTERNATIONAL INC. (70210)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

TEMFLEX 105C 0 AWG WHITE MINNESOTA MINING AND MFG CO 3M (75037)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

TEMFLEX 105C 0 AWG WHITE 3M COMPANY (76381)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

Also filed by the same company as TEMFLEX 105C 0 AWG WHITE (20999) — one product, several catalogue rows.

TURBOTRANS 105 PRYSMIAN CABLES AND SYSTEMS USA, LL (71124)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

What defines this item

Specifications and drawings the catalogue records against this number. These are what the parts above are made to — never alternatives to them.

Historical & informational references

Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.

3003 MINNESOTA MINING AND MFG CO 3M (75037)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

3003 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL1389610 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

ASTRA 703/105 ESSEX GROUP INC SUFLEX/IWP DIV (91094)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

GS830L-312W NORTHROP GRUMMAN SYSTEMS CORPORATION (26512)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

TEMFLEX 105C 5/16 IN WHITE MINNESOTA MINING AND MFG CO 3M (75037)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

TEMFLEX 105C 5/16 IN WHITE 3M COMPANY (76381)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

TEMFLEX 105C 5/16 IN WHITE 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Substitutes — other stock numbers

Codified interchangeability across stock numbers (FLIS I&S), with the catalogue's order of use where it states one.

PVC-105-5/16-3 BELDEN, INC.

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-050-5659

WALL THICKNESS: 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 630.0 VOLTS PER MIL /0.001 INCH/ INSIDE DIAMETER: 0.313 INCHES MINIMUM AND 0.334 INCHES MAXIMUM COLOR: WHITE

PVC-105-5/16WHITE BELDEN, INC.

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-050-5659

WALL THICKNESS: 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 630.0 VOLTS PER MIL /0.001 INCH/ INSIDE DIAMETER: 0.313 INCHES MINIMUM AND 0.334 INCHES MAXIMUM COLOR: WHITE

Stated characteristics

The codification record's own dimensions and material statements — official, and public by nature.

WALL THICKNESS0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUMFLIS characteristics (MRC)
RELIABILITY INDICATORNOT ESTABLISHEDFLIS characteristics (MRC)
INSIDE DIAMETER0.313 INCHES MINIMUM AND 0.334 INCHES MAXIMUMFLIS characteristics (MRC)
TEMP RATING-10.0 CELSIUS AND 105.0 CELSIUSFLIS characteristics (MRC)
ENVIRONMENTAL PROTECTIONHEAT RESISTANTFLIS characteristics (MRC)
MINIMUM TENSILE STRENGTH1800 POUNDS PER SQUARE INCHFLIS characteristics (MRC)
FLEXIBILITYFLEXIBLEFLIS characteristics (MRC)
COLORWHITEFLIS characteristics (MRC)
MATERIALPLASTIC POLYVINYL CHLORIDE (PVC)FLIS characteristics (MRC)
STYLE DESIGNATORNONSHRINKABLEFLIS characteristics (MRC)
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS630.0 VOLTS PER MIL /0.001 INCH/FLIS characteristics (MRC)
NONDEFINITIVE SPEC/STD DATA1 CATEGORY AND I CLASS AND U FORM AND C GRADE AND 5/16 IN. SIZE AND UA SUBFORM AND F TYPEFLIS characteristics (MRC)
DEPARTURE FROM CITED DOCUMENTAS MOD BY COLORFLIS characteristics (MRC)

Take the family with you

The whole group as CSV — members, makers, stock numbers and order of use.

Export paused

The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.

Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.

Staying inside the regulation — routes from candidate to approved

Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).

  1. Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
  2. Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
  3. Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
  4. Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
  5. FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
  6. Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.

Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.

Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.

Source: DLA Logistics Information Services (FLIS) · cycle 2026-0 · official codification

This crosswalk identifies candidate equivalents with cited evidence. It is not an airworthiness approval. Substitution decisions remain subject to your organisation’s procurement and engineering approval process and the governing maintenance data (AMM/CMM/SRM/CML/OMAT).