Trail

Consumables & expendables · Spec-Crosswalk

INSULATION SLEEVING,ELECTRICAL

Stock number · one item of supply — the parts codified against it, and the stock numbers it substitutes for

← Search another part, spec or stock number

Purchasable unitnone derived yet
Part number3 approved sources
You are here · Stock number5970-00-082-3942
Specificationnone cited

Approved sources

Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.

BACT63A54-9 THE BOEING COMPANY (81205)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

GS830CV19-9 NORTHROP GRUMMAN SYSTEMS CORPORATION (26512)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

M23053-4-102-9 THE BOEING COMPANY (76301)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

MMS-809-9-T3/16 THE BOEING COMPANY (76301)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

065-001756-019 NORTHROP GRUMMAN SYSTEMS CORPORATIO (26916)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

1130389G22 L3HARRIS TECHNOLOGIES, INC. (31550)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11699912-122 ARMY, UNITED STATES DEPARTMENT OF T (19204)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11830621-150 COMBAT CAPABILITIES DEVELOPMENT (19203)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

119A2290-150 GENERAL DYNAMICS-OTS, INC. (05606)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

224845-905 BAE SYSTEMS INFORMATION AND ELECTRO (81413)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

344635-5 RAYTHEON COMPANY (3B150)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

4000093 AMETEK, INC. (99564)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

446320-205 RAYTHEON COMPANY (37695)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

44791JP1883U9 NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

44791JP1883U9 WESTINGHOUSE ELECTRIC CORP (79500)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

44791JP188WHITE NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

48-00004-208 RAYTHEON COMPANY (00724)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

5053082106 TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

59199-05 SAINT-GOBAIN PERFORMANCE PLASTICS (09795)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

7956686-04 NORTHROP GRUMMAN SYSTEMS CORPORATIO (03956)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

816TE0060 FINMECCANICA SPA (A0199)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

9116C005-5 BAE SYSTEMS INFORMATION AND ELECTRO (94117)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

94-0051 BAE SYSTEMS INFORMATION & ELECTRONI (19397)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FP301-1-48-9 HELLERMANNTYTON LIMITED (K1793)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

G340002-9 L3HARRIS TECHNOLOGIES, INC (24930)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

MP-M0013-105 RAYTHEON E-SYSTEMS, INC (33875)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

PENNTUBE V FLEXIBLE 3/16IN WHT SAINT-GOBAIN PERFORMANCE PLASTICS (09795)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

PO135 3/16IN WHITE MARKEL CORP. (03890)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF100-1 3/16INWHITE TE CONNECTIVITY (K1010)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF100-1-3-16WHITE TE CONNECTIVITY (K1010)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

ST-221-3/16IN WHITE MANHATTAN/CDT COLE-FLEX (56352)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

VERSAFIT-3/16-9-SP TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

152-3989-000 MARKEL CORP. (03890)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

2526070P19 NAVAL SEA SYSTEMS COMMAND (53711)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

3020952-7-1 GULF COAST HOLDINGS, INC (0DHG4)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

44731JP764 NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

44791JP187WHT NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

45-033344-04 NORTHROP GRUMMAN SYSTEMS CORPORATIO (26916)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

591-0222-003 THE BOEING COMPANY (94756)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

AVF-3/16-9 ESSEX GROUP INC SUFLEX/IWP DIV (91094)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

MPD11862CLASS1WH1TESIZE3-16 US ARMY AVIATION AND MISSILE COMMAND (18876)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

RNF-100-121-9 TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

RNF100-3-16W TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

S9352-10-9-100 HONEYWELL INTERNATIONAL INC. (70210)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

S9352-10-9-108 HONEYWELL INTERNATIONAL INC. (99193)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

What defines this item

Specifications and drawings the catalogue records against this number. These are what the parts above are made to — never alternatives to them.

  • AMS-DTL-23053/5 — SAE (AS / AMS) (specification · not yet a document in the graph)
  • M23053/-105-9 — Military Specifications (specification · not yet a document in the graph)
  • M23053/5-104-9 — Military Specifications (specification · not yet a document in the graph)
  • M23053/5-105-9 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053-10 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053/5 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053/5-1 — Military Specifications (specification · not yet a document in the graph)
  • MS23053/5-105-9 — Military Standards (MS) (specification · not yet a document in the graph)
  • SAE-AMS-DTL-23053/5 — SAE (AS / AMS) (specification · not yet a document in the graph)
  • SAE-AS23053/5 — SAE International (AS / AMS) (specification · not yet a document in the graph)

Historical & informational references

Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.

10134036 NIMIKKEISTOKESKUS NCB FINLAND (A486G)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

2526070PC19 NAVAIR AND NAVSEA MANAGED ORIGINAL (10001)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

344635-5 RAYTHEON COMPANY (49956)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

4000093 L3HARRIS INTERSTATE ELECTRONICS (07421)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

45-033344-04 NORTHROP GRUMMAN SYSTEMS (15280)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

591-0147-005 THE BOEING COMPANY (94756)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL0812355 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL0839355 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL1391662 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

7230941-P25 LOCKHEED MARTIN CORPORATION (03538)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

7956686-04 LOCKHEED MARTIN CORP (90536)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

9116C005-5 LOCKHEED CORP LOCKHEED ELECTRONICS (87557)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

FIT-221 3/16IN WHITE BELDEN, INC. (92194)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

FP301-1 3/16IN WHITE 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

R2479P5 LOCKHEED MARTIN CORPORATION (23991)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100-3/16-WH-SP TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100TYPE1 3/16IN WHITE TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF100 3/16IN WHITE TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF100-1-3-16WHITE TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RT876-3/16-WHITE TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

S9052-10-9-100 HONEYWELL INTERNATIONAL INC. (70210)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

S9352-10-9 HONEYWELL INTERNATIONAL INC. (70210)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

ST0150AB0052CL1 3/16-9 THE BOEING COMPANY (94756)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

VFP876-3/16 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Y00037-005 BAE SYSTEMS INFORMATION AND ELECTRO (12436)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Substitutes — other stock numbers

Codified interchangeability across stock numbers (FLIS I&S), with the catalogue's order of use where it states one.

48-00004-208 RAYTHEON COMPANY

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-082-3942

RECOVERED WALL THICKNESS: 0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 500.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 0.187 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.093 INCHES MAXIMUM

MS63-87 3/16IN WHITE TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-01-185-5382

OVERALL LENGTH: 200.000 FEET MINIMUM RECOVERED WALL THICKNESS: 0.020 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 500.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 0.187 INCHES NOMINAL

RNF100-3-16WHITE TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-01-054-1709

RECOVERED WALL THICKNESS: 0.020 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 1300.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 0.187 INCHES NOMINAL RECOVERED INSIDE DIAMETER: 0.093 INCHES NOMINAL

Stated characteristics

The codification record's own dimensions and material statements — official, and public by nature.

RELIABILITY INDICATORNOT ESTABLISHEDFLIS characteristics (MRC)
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUSFLIS characteristics (MRC)
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANTFLIS characteristics (MRC)
EXPANDED INSIDE DIAMETER0.187 INCHES MINIMUMFLIS characteristics (MRC)
RECOVERED INSIDE DIAMETER0.093 INCHES MAXIMUMFLIS characteristics (MRC)
RECOVERED WALL THICKNESS0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUMFLIS characteristics (MRC)
HEAT SHRINKAGE RATING IN PERCENT50.0FLIS characteristics (MRC)
END ITEM IDENTIFICATIONMRAP - COUGAR; A4 BRADLEY FIGHTING VEHICLE; A3 BRADLEY FIGHTING VEHICLEFLIS characteristics (MRC)
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCHFLIS characteristics (MRC)
FLEXIBILITYFLEXIBLEFLIS characteristics (MRC)
COLORWHITEFLIS characteristics (MRC)
MATERIALPLASTIC CROSS-LINKED POLYOLEFINFLIS characteristics (MRC)
STYLE DESIGNATORSHRINKABLEFLIS characteristics (MRC)
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS500.0 VOLTS PER MIL /0.001 INCH/FLIS characteristics (MRC)

Take the family with you

The whole group as CSV — members, makers, stock numbers and order of use.

Export paused

The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.

Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.

Staying inside the regulation — routes from candidate to approved

Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).

  1. Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
  2. Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
  3. Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
  4. Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
  5. FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
  6. Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.

Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.

Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.

Source: DLA Logistics Information Services (FLIS) · cycle 2026-0 · official codification

This crosswalk identifies candidate equivalents with cited evidence. It is not an airworthiness approval. Substitution decisions remain subject to your organisation’s procurement and engineering approval process and the governing maintenance data (AMM/CMM/SRM/CML/OMAT).