Trail

Consumables & expendables · Spec-Crosswalk

INSULATION SLEEVING,ELECTRICAL

Stock number · one item of supply — the parts codified against it, and the stock numbers it substitutes for

← Search another part, spec or stock number

Purchasable unitnone derived yet
Part number4 approved sources
You are here · Stock number5970-00-815-1300
Specificationnone cited

Approved sources

Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.

MMS809-0-1 THE BOEING COMPANY (76301)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SS7072A1000Z SIKORSKY AIRCRAFT CORPORATION (78286)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

152-3975-000 ROCKWELL COLLINS, INC. (13499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

BACT63A59-0 THE BOEING COMPANY (81205)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

MMS809 THE BOEING COMPANY (76301)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

0097832 GENERAL DYNAMICS LAND SYSTEMS - CAN (56161)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

0097832 DENEL VEHICLE SYSTEMS (SZ177)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

065-001756-010 NORTHROP GRUMMAN SYSTEMS CORPORATIO (26916)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

1130389G46 L3HARRIS TECHNOLOGIES, INC. (31550)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11830621-159 COMBAT CAPABILITIES DEVELOPMENT (19203)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

119A2290-159 GENERAL DYNAMICS-OTS, INC. (05606)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

162-0573-00 TEKTRONIX, INC. (80009)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

224845-010 BAE SYSTEMS INFORMATION AND ELECTRO (81413)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

2576911-10 NAVAIR AND NAVSEA MANAGED ORIGINAL (10001)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

2587793-1 NAVAL SHIP SYSTEMS COMMAND (80064)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

417177-10 RAYTHEON COMPANY (96214)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

446320-110 RAYTHEON COMPANY (37695)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

44791JP0010U0 NORTHROP GRUMMAN SUPPORT SERVICES C (48306)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

48-00004-017 RAYTHEON COMPANY (00724)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

558005-10 ELDEC AEROSPACE CORP (08748)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

6086085-10 LOCKHEED MARTIN CORPORATION (03640)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

816TE0071 FINMECCANICA SPA (A0199)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

915390C1 SOLAR TURBINES INCORPORATED (66195)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

921C4015-01-029 GE AVIATION SYSTEMS LLC DBA GE (86360)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

94-0036 BAE SYSTEMS INFORMATION & ELECTRONI (19397)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

9979095-10 US ARMY AVIATION AND MISSILE COMMAND (18876)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

GMS5-20-31-0 LOCKHEED MARTIN CORPORATION (25500)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

M23053/5-110-0 LEONARDO SPA HELICOPTERS DIVISION - (A0126)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

PENNTUBE V FLEXIBLE 1IN BLACK SAINT-GOBAIN PERFORMANCE PLASTICS (09795)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

ST-221-1IN BLACK MANHATTAN/CDT COLE-FLEX (56352)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SUMI-B2-1-0 CAMBRIDGE TECHNOLOGIES (Z1N72)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

1147AS363-6 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS364-6 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS365-5 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS366-4 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS370-4 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS371-5 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS375-3 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS379-4 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS407-4 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS605-7 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1147AS620-2 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

12295791-10 U S ARMY TANK AUTOMOTIVE COMMAND (19207)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

267M0048P076 RAYTHEON COMPANY (49956)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

344636-10 RAYTHEON COMPANY (3B150)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

400-7057932 PC NAVAL SEA SYSTEMS COMMAND (53711)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

417177-10 ELETTRONICA ASTER SPA (A0267)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

591-0222-020 THE BOEING COMPANY (94756)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

59100-10 SAINT-GOBAIN PERFORMANCE PLASTICS (09795)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

7555405P10 LOCKHEED MARTIN CORP NAVAL (99971)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

F1270063 LOCKHEED MARTIN CORP (04236)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

FIT-105-1 BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

FIT-221-1 BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

FIT221-1BLACK BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

MIS14310CL1BLACK1-000ID US ARMY AVIATION AND MISSILE COMMAND (18876)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

MMS809 SCM CORP (74133)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

MPD11862 US ARMY AVIATION AND MISSILE COMMAND (18876)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

P0135 1IN BLACK MARKEL CORP. (03890)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

PENNTUBEV1INBLK SAINT-GOBAIN PERFORMANCE PLASTICS (09795)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

What defines this item

Specifications and drawings the catalogue records against this number. These are what the parts above are made to — never alternatives to them.

  • AMS-DTL-23053/5 — SAE (AS / AMS) (specification · not yet a document in the graph)
  • M23053/5-110-0 — Military Specifications (specification · not yet a document in the graph)
  • M23053/5-210-0 — Military Specifications (specification · not yet a document in the graph)
  • M81786-3-10 — Military Specifications (specification · not yet a document in the graph)
  • M81786-5-1 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053/5 — Military Specifications (specification · not yet a document in the graph)
  • SAE-AS23053/5 — SAE International (AS / AMS) (specification · not yet a document in the graph)

Historical & informational references

Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.

0097832-FH00 DENEL VEHICLE SYSTEMS (SZ177)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

344636-10 RAYTHEON COMPANY (49956)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

4000201 L3HARRIS INTERSTATE ELECTRONICS (07421)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

44791JP0010U0 NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

45-033344-06 NORTHROP GRUMMAN SYSTEMS (15280)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL1389366 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

7230941-P60 LOCKHEED MARTIN CORPORATION (03538)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

754-0152-008 NORTHERN TELECOM INC TELECOM (62143)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

915390C1 RTX CORPORATION (55820)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

FP301-1 1IN BLACK 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

FPS-064-BLK SPC TECHNOLOGY - NEWARK (63590)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

MRS4651-S1-0 NORTHROP GRUMMAN SYSTEMS CORPORATION (76823)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

R2479P30 LOCKHEED MARTIN CORPORATION (23991)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100-1-BK-SP TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100TYPE1 1IN BLACK TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Y00037-010 BAE SYSTEMS INFORMATION AND ELECTRO (12436)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Substitutes — other stock numbers

Codified interchangeability across stock numbers (FLIS I&S), with the catalogue's order of use where it states one.

48-00004-017 RAYTHEON COMPANY

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-815-1300

RECOVERED WALL THICKNESS: 0.030 INCHES MINIMUM AND 0.040 INCHES MAXIMUM DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 500.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 1.000 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.500 INCHES MAXIMUM

PVC1INBLACK TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-945-2848

RECOVERED WALL THICKNESS: 0.040 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 400.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 1.000 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.500 INCHES MAXIMUM

RT-876 1.0ID BLACK TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-768-9370

RECOVERED WALL THICKNESS: 0.035 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 500.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 1.000 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.500 INCHES MAXIMUM

RT876-1 TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-434-4159

RECOVERED WALL THICKNESS: 0.035 INCHES NOMINAL EXPANDED INSIDE DIAMETER: 1.000 INCHES NOMINAL RECOVERED INSIDE DIAMETER: 0.500 INCHES NOMINAL MATERIAL: PLASTIC POLYOLEFIN

Stated characteristics

The codification record's own dimensions and material statements — official, and public by nature.

RELIABILITY INDICATORNOT ESTABLISHEDFLIS characteristics (MRC)
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUSFLIS characteristics (MRC)
ENVIRONMENTAL PROTECTIONCRACK RESISTANTFLIS characteristics (MRC)
EXPANDED INSIDE DIAMETER1.000 INCHES MINIMUMFLIS characteristics (MRC)
RECOVERED INSIDE DIAMETER0.500 INCHES MAXIMUMFLIS characteristics (MRC)
RECOVERED WALL THICKNESS0.030 INCHES MINIMUM AND 0.040 INCHES MAXIMUMFLIS characteristics (MRC)
HEAT SHRINKAGE RATING IN PERCENT50.0FLIS characteristics (MRC)
END ITEM IDENTIFICATIONMRAP RG-31; MRAP RG-33; MULTIPLE LAUNCH ROCKET SYSTEM (MLRS)FLIS characteristics (MRC)
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCHFLIS characteristics (MRC)
FLEXIBILITYFLEXIBLEFLIS characteristics (MRC)
COLORBLACKFLIS characteristics (MRC)
MATERIALPLASTIC CROSS-LINKED POLYOLEFINFLIS characteristics (MRC)
STYLE DESIGNATORSHRINKABLEFLIS characteristics (MRC)
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS500.0 VOLTS PER MIL /0.001 INCH/FLIS characteristics (MRC)

Take the family with you

The whole group as CSV — members, makers, stock numbers and order of use.

Export paused

The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.

Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.

Staying inside the regulation — routes from candidate to approved

Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).

  1. Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
  2. Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
  3. Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
  4. Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
  5. FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
  6. Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.

Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.

Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.

Source: DLA Logistics Information Services (FLIS) · cycle 2026-0 · official codification

This crosswalk identifies candidate equivalents with cited evidence. It is not an airworthiness approval. Substitution decisions remain subject to your organisation’s procurement and engineering approval process and the governing maintenance data (AMM/CMM/SRM/CML/OMAT).