Trail

Consumables & expendables · Spec-Crosswalk

INSULATION SLEEVING,ELECTRICAL

Stock number · one item of supply — the parts codified against it, and the stock numbers it substitutes for

← Search another part, spec or stock number

Purchasable unitnone derived yet
Part number2 approved sources
You are here · Stock number5970-00-892-0970
Specificationnone cited

Approved sources

Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.

37S130315-13-1 HERLEY CHICAGO (98738)

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)

PVC105-10CLEAR BELDEN, INC. (92194)

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

design-control reference — the reference that controls this item of supply (RNCC 3 · RNVC 2)

325511-13 TRANSICO, INC. DBA EECO SWITCH (97525)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

44791AB1063UA NORTHROP GRUMMAN SUPPORT SERVICES C (48306)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

591-0008-007 THE BOEING COMPANY (94756)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

80-1760-2126-1 3M DEUTSCHLAND GMBH (D2607)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FLEXITE HT-105C MARKEL CORP. (03890)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

ITCO 929 PEXCO LLC (12509)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

P-105/10-1 MANHATTAN/CDT COLE-FLEX (56352)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

TURBOLEX 105 PRYSMIAN CABLES AND SYSTEMS USA, LL (71124)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

2686572-06 NAVAIR AND NAVSEA MANAGED ORIGINAL (10001)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

D105&10CLEAR DABURN WIRE & CABLE CORP (25706)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

NATVAT 400/461 HIGH VOLTAGE ENGINEERING CORP NATVAR (96904)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

What defines this item

Specifications and drawings the catalogue records against this number. These are what the parts above are made to — never alternatives to them.

  • MIL-I-631 — Military Specifications
  • SM-A-680088-13 — US Army CECOM (SM- / SC- / A3 drawings) (specification · not yet a document in the graph)

Historical & informational references

Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.

3003 MINNESOTA MINING AND MFG CO 3M (75037)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

3003 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

44791AB1063UA NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

ASTRA 703/105 ESSEX GROUP INC SUFLEX/IWP DIV (91094)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

GS830L-10C NORTHROP GRUMMAN SYSTEMS CORPORATION (26512)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

TEMFLEX 105C 10 AWG CLEAR 3M COMPANY (76381)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

TEMFLEX 105C 10 AWG CLEAR MINNESOTA MINING AND MFG CO 3M (75037)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

TEMFLEX 105C 10 AWG CLEAR 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Substitutes — other stock numbers

Codified interchangeability across stock numbers (FLIS I&S), with the catalogue's order of use where it states one.

37S130315-13-1 HERLEY CHICAGO

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-892-0970

WALL THICKNESS: 0.016 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 800.0 VOLTS PER MIL /0.001 INCH/ INSIDE DIAMETER: 0.106 INCHES NOMINAL COLOR: CLEAR

PVC105-10CLEAR BELDEN, INC.

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-892-0970

WALL THICKNESS: 0.016 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 800.0 VOLTS PER MIL /0.001 INCH/ INSIDE DIAMETER: 0.106 INCHES NOMINAL COLOR: CLEAR

Stated characteristics

The codification record's own dimensions and material statements — official, and public by nature.

WALL THICKNESS0.016 INCHES NOMINALFLIS characteristics (MRC)
RELIABILITY INDICATORNOT ESTABLISHEDFLIS characteristics (MRC)
INSIDE DIAMETER0.106 INCHES NOMINALFLIS characteristics (MRC)
TEMP RATING-10.0 CELSIUS AND 70.0 CELSIUSFLIS characteristics (MRC)
ENVIRONMENTAL PROTECTIONHEATFLIS characteristics (MRC)
MINIMUM TENSILE STRENGTH1800 POUNDS PER SQUARE INCHFLIS characteristics (MRC)
SPECIAL FEATURESMATERIAL SPEC: MIL-I-631, TYPE F, FORM U, SUBFORM UA, GRADE C, CLASS 1, CATEGORY 1FLIS characteristics (MRC)
FLEXIBILITYFLEXIBLEFLIS characteristics (MRC)
COLORCLEARFLIS characteristics (MRC)
MATERIALPLASTIC POLYVINYL CHLORIDE (PVC)FLIS characteristics (MRC)
STYLE DESIGNATORNONSHRINKABLEFLIS characteristics (MRC)
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS800.0 VOLTS PER MIL /0.001 INCH/FLIS characteristics (MRC)
NONDEFINITIVE SPEC/STD DATA1 CATEGORY AND I CLASS AND U FORM AND C GRADE AND 10AWG SIZE AND UA SUBFORM AND F TYPEFLIS characteristics (MRC)

Take the family with you

The whole group as CSV — members, makers, stock numbers and order of use.

Export paused

The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.

Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.

Staying inside the regulation — routes from candidate to approved

Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).

  1. Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
  2. Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
  3. Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
  4. Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
  5. FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
  6. Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.

Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.

Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.

Source: DLA Logistics Information Services (FLIS) · cycle 2026-0 · official codification

This crosswalk identifies candidate equivalents with cited evidence. It is not an airworthiness approval. Substitution decisions remain subject to your organisation’s procurement and engineering approval process and the governing maintenance data (AMM/CMM/SRM/CML/OMAT).