Approved sources
Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.
OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
GS830CV05-0 NORTHROP GRUMMAN SYSTEMS CORPORATION (26512)
POSSIBLE
OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
1180621-141 COMBAT CAPABILITIES DEVELOPMENT (19203)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
2576911-1 NAVAIR AND NAVSEA MANAGED ORIGINAL (10001)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
4000104 AMETEK, INC. (99564)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
417177-1 RAYTHEON COMPANY (96214)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
6086085-1 LOCKHEED MARTIN CORPORATION (03640)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
691C838P1 BAE SYSTEMS CONTROLS INC. (89954)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
94-0021 BAE SYSTEMS INFORMATION & ELECTRONI (19397)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
945892-1010 NORTHROP GRUMMAN SYSTEMS CORPORATIO (06481)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
9979095-1 US ARMY AVIATION AND MISSILE COMMAND (18876)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
Y00037-001 BAE SYSTEMS INFORMATION AND ELECTRO (12436)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
344636-1 RAYTHEON COMPANY (3B150)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
59100-01 SAINT-GOBAIN PERFORMANCE PLASTICS (09795)
POSSIBLE
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
INSULATION SLEEVING,ELECTRICAL
codified reference — recorded against this stock number; the catalogue grade is not held
Historical & informational references
Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
10134033 NIMIKKEISTOKESKUS NCB FINLAND (A486G)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
2576911-001 NAVAIR AND NAVSEA MANAGED ORIGINAL (10001)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
344636-1 RAYTHEON COMPANY (49956)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
4000104 L3HARRIS INTERSTATE ELECTRONICS (07421)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
7230941-P51 LOCKHEED MARTIN CORPORATION (03538)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
829-005-002 NAVCOM DEFENSE ELECTRONICS, INC. (57057)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
PF70E24-0 RSCC WIRE & CABLE LLC (90484)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
R2479P21 LOCKHEED MARTIN CORPORATION (23991)
WITHDRAWN
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
INSULATION SLEEVING,ELECTRICAL
no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it
Stated characteristics
The codification record's own dimensions and material statements — official, and public by nature.
RELIABILITY INDICATORNOT ESTABLISHEDFLIS characteristics (MRC)
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUSFLIS characteristics (MRC)
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANTFLIS characteristics (MRC)
EXPANDED INSIDE DIAMETER0.046 INCHES MINIMUMFLIS characteristics (MRC)
RECOVERED INSIDE DIAMETER0.023 INCHES MAXIMUMFLIS characteristics (MRC)
RECOVERED WALL THICKNESS0.016 INCHES NOMINALFLIS characteristics (MRC)
HEAT SHRINKAGE RATING IN PERCENT50.0FLIS characteristics (MRC)
END ITEM IDENTIFICATIONMULTIPLE LAUNCH ROCKET SYSTEM (MLRS)FLIS characteristics (MRC)
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCHFLIS characteristics (MRC)
FLEXIBILITYFLEXIBLEFLIS characteristics (MRC)
COLORBLACKFLIS characteristics (MRC)
MATERIALPLASTIC CROSS-LINKED POLYOLEFINFLIS characteristics (MRC)
STYLE DESIGNATORSHRINKABLEFLIS characteristics (MRC)
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS500.0 VOLTS PER MIL /0.001 INCH/FLIS characteristics (MRC)
Staying inside the regulation — routes from candidate to approved
Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).
- Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
- Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
- Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
- Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
- FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
- Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.
Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.
Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.