Trail

Consumables & expendables · Spec-Crosswalk

INSULATION SLEEVING,ELECTRICAL

Stock number · one item of supply — the parts codified against it, and the stock numbers it substitutes for

← Search another part, spec or stock number

Purchasable unitnone derived yet
Part number7 approved sources
You are here · Stock number5970-01-008-4805
Specificationnone cited

Approved sources

Every maker's reference the catalogue files against this item of supply — the parts someone holding this number can use. The design-control reference is the one that controls the item; a secondary reference is a real codified fact and a weaker one.

130-005-7 BELL TEXTRON INC (97499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SS7072A0375Z SIKORSKY AIRCRAFT CORPORATION (78286)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

130-005-7-21 BELL TEXTRON INC (97499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

130-005-7-38 BELL TEXTRON INC (97499)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

S2014-18B96 NORTHROP GRUMMAN SYSTEMS CORPORATION (26512)

POSSIBLE

OEM source-control number — the OEM’s own reference for this item; the sources beneath answer it. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

0097829 GENERAL DYNAMICS LAND SYSTEMS - CAN (56161)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

0097829 DENEL VEHICLE SYSTEMS (SZ177)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

065-001756-007 NORTHROP GRUMMAN SYSTEMS CORPORATIO (26916)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

08-196485-07 LOCKHEED MARTIN CORPORATION (11530)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

082201159014 THALES NEDERLAND B.V. (H0203)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

1130389G31 L3HARRIS TECHNOLOGIES, INC. (31550)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11699912-41 ARMY, UNITED STATES DEPARTMENT OF T (19204)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

11830621-153 COMBAT CAPABILITIES DEVELOPMENT (19203)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

119A2290-153 GENERAL DYNAMICS-OTS, INC. (05606)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

13272-11 CELAB LTD (U2888)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

204421 DGA/DO/UM ESIO (F5350)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

224845-007 BAE SYSTEMS INFORMATION AND ELECTRO (81413)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

303558 WIBA ZEVENAAR B.V. (H0G87)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

344636-7 RAYTHEON COMPANY (3B150)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

4000098 AMETEK, INC. (99564)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

417177-7 RAYTHEON COMPANY (96214)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

44791JP3753U0 NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

512822-10-1 BOWMAR LLC (99479)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

532-022 TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

532-022 THE CHARLES STARK DRAPER LABORATORY (51993)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

532-022-105 L3HARRIS INTERSTATE ELECTRONICS (07421)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

558005-06 ELDEC AEROSPACE CORP (08748)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

59100-07 SAINT-GOBAIN PERFORMANCE PLASTICS (09795)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

6086085-7 LOCKHEED MARTIN CORPORATION (03640)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

618AS337-7 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

6SE00682-9 NAVAL AIR WARFARE CENTER AIRCRAFT (80020)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

816TE0065 FINMECCANICA SPA (A0199)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

874576 COMBAT CAPABILITIES DEVELOPMENT (19203)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

915/4/08061/206-H BAE SYSTEMS (DEFENCE SYSTEMS) LTD (U2982)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

915250C1 SOLAR TURBINES INCORPORATED (66195)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

921C4015-01-024 GE AVIATION SYSTEMS LLC DBA GE (86360)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

94-0030 BAE SYSTEMS INFORMATION & ELECTRONI (19397)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

9554869492 SAFRAN HELICOPTER ENGINES (F0228)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

99002493 THALES DEFENCE DEUTSCHLAND GMBH (D2416)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

9979095-7 US ARMY AVIATION AND MISSILE COMMAND (18876)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

C2017-7 LOCKHEED MARTIN CORPORATION (81755)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

FIT-221-3/8BLACK BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

GMS5-20-20-0 LOCKHEED MARTIN CORPORATION (25500)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

P0135 3/8IN BLACK MARKEL CORP. (03890)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF-100-3/8-0-SP TE CONNECTIVITY (K1010)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

RNF1001 3-8BLACK TE CONNECTIVITY CORPORATION (06090)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SH290-3/8 DABURN WIRE & CABLE CORP (25706)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

ST-221-3/8IN BLACK MANHATTAN/CDT COLE-FLEX (56352)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

SUMI-B2-3/8-0 CAMBRIDGE TECHNOLOGIES (Z1N72)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

secondary reference — also codified against this stock number, as a secondary reference (RNCC 5)

1147AS465-3 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

1210AS185-13 NAVAL AIR SYSTEMS COMMAND MANAGED (30003)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

2296632P14 NAVAL SEA SYSTEMS COMMAND (53711)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

267M0048P046 RAYTHEON COMPANY (49956)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

417177-7 HENSOLDT SENSORS GMBH (C0426)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

Also filed by the same company as 417177-7 (D1901) — one product, several catalogue rows.

417177-7 ELETTRONICA ASTER SPA (A0267)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

44791J97AR 3/8IN BLACK NORTHROP GRUMMAN SYSTEMS CORPORATIO (97942)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

7555405P7 LOCKHEED MARTIN CORP NAVAL (99971)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

7956003-01 LOCKHEED MARTIN CORP (90536)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

802033-375 EVANS & SUTHERLAND COMPUTER CORP (53938)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

FIT105 3/8 BELDEN, INC. (92194)

POSSIBLE

INSULATION SLEEVING,ELECTRICAL

codified reference — recorded against this stock number; the catalogue grade is not held

+ 7 more sources held.

What defines this item

Specifications and drawings the catalogue records against this number. These are what the parts above are made to — never alternatives to them.

  • 225154121601 — NCB Hungary — national codification bureau (Honvédségi service designations) (specification · not yet a document in the graph)
  • 757592992301 — NCB Hungary — national codification bureau (Honvédségi service designations) (specification · not yet a document in the graph)
  • AMS-DTL-23053/5 — SAE (AS / AMS) (specification · not yet a document in the graph)
  • AMS3587-0.375DIA,BLK — SAE (AS / AMS) (specification · not yet a document in the graph)
  • M23053/5 — Military Specifications (specification · not yet a document in the graph)
  • M23053/5-007-0 — Military Specifications (specification · not yet a document in the graph)
  • M23053/5-107 — SAE International (AS / AMS) (specification · not yet a document in the graph)
  • M23053/5-107-0 — SAE (AS / AMS) (specification · not yet a document in the graph)
  • M81786/3-7 — Military Specifications (specification · not yet a document in the graph)
  • MIL-DTL-23053/5-107-12 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053/2 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053/5 — Military Specifications (specification · not yet a document in the graph)
  • MIL-I-23053/5CL — Military Specifications (specification · not yet a document in the graph)
  • MILI23053ACL1-0X — Military Specifications (specification · not yet a document in the graph)
  • MS23053/5-107-0 — Military Standards (MS) (specification · not yet a document in the graph)
  • SAE-AS23053/5 — SAE International (AS / AMS) (specification · not yet a document in the graph)
  • SAE-DTL-23053 — SAE International (AS / AMS) (specification · not yet a document in the graph)
  • SAE-DTL-23053/5-107-12 — SAE International (AS / AMS) (specification · not yet a document in the graph)

Historical & informational references

Numbers the catalogue records against this item but marks as not for procurement — withdrawn entries, information-only listings, drawings, and references that need more than the number to identify the item. If you arrived holding one of these, this is the item it points to; the sources above are what can actually be used.

0097829-FH00-001 DENEL VEHICLE SYSTEMS (SZ177)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

10362765 NIMIKKEISTOKESKUS NCB FINLAND (A486G)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

2526070PC7 NAVAIR AND NAVSEA MANAGED ORIGINAL (10001)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

2576911-7 NAVAIR AND NAVSEA MANAGED ORIGINAL (10001)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

344636-7 RAYTHEON COMPANY (49956)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

4000098 L3HARRIS INTERSTATE ELECTRONICS (07421)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

45-033344-09 NORTHROP GRUMMAN SYSTEMS (15280)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

54A0003-060 UNISYS CORP (4S536)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL1391559 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

5970PL1709572 JEDNOLITY INDEKS MATERIALOWY - (9009H)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

6SE00682-9 NAVAL AIR WARFARE CENTER AIRCRAFT (28638)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

7230941-P57 LOCKHEED MARTIN CORPORATION (03538)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

754-0152-004 NORTHERN TELECOM INC TELECOM (62143)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

915250C1 RTX CORPORATION (55820)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

99002493 THALES COMMUNICATIONS (F0053)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

FP-301,3/8IN,BLA 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

FP301-1 3/8IN BLACK 3M CO ADMININISTRATIVE ELECTRONIC & (20999)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

G395966-7 AMERICAN TELEPHONE AND TELEGRAPH CO (64959)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

G395966-7 LUCENT TECHNOLOGIES INC ADVANCED (01714)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

GP0-135-3/8IN-CLASS 3,BLACK REMTEK CORP (59659)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

GPO-135 3/8IN BLACK REMTEK CORP (59659)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

R2479P27 LOCKHEED MARTIN CORPORATION (23991)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100 3/8IN BLACK TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100 TYPE1 3/8IN BLACK TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100-3/8-BK-SP TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100TUPE1 3/8IN BLACK TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF-100TYPE1,3/8IN,BLACK TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF100-1-3-8BLACK TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

RNF100-3-8BLACK TE CONNECTIVITY CORPORATION (06090)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

SS7072A0375Z050 SIKORSKY AIRCRAFT CORPORATION (78286)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Y00037-007 BAE SYSTEMS INFORMATION AND ELECTRO (12436)

WITHDRAWN

INSULATION SLEEVING,ELECTRICAL

no longer valid — this reference was withdrawn from the catalogue record (RNVC 9) — the history trail: hold it, do not buy to it

Substitutes — other stock numbers

Codified interchangeability across stock numbers (FLIS I&S), with the catalogue's order of use where it states one.

MMS809-0-3-8 THE BOEING COMPANY

CONFIRMED

OEM source-control number — the OEM’s own reference for this item; the other members are its approved sources per codification. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

NSN 5970-01-008-4805

OVERALL LENGTH: 0.562 INCHES NOMINAL RECOVERED WALL THICKNESS: 0.025 INCHES NOMINAL EXPANDED INSIDE DIAMETER: 0.375 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.187 INCHES MAXIMUM

Y1155-6-7 BREEZE-EASTERN LLC

CONFIRMED

OEM source-control number — the OEM’s own reference for this item; the other members are its approved sources per codification. All of this OEM’s references →

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-054-3388

RECOVERED WALL THICKNESS: 0.030 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 570.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 0.375 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.187 INCHES NOMINAL

225154121601 NCB HUNGARY (HONVEDSEGI EGYSEGES

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-954-1624

AS23053/5-107-0 SAE INTERNATIONAL

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-01-695-1701

WALL THICKNESS: 0.025 INCHES NOMINAL RECOVERED WALL THICKNESS: 0.025 INCHES NOMINAL INSIDE DIAMETER: 0.187 INCHES MINIMUM AND 0.375 INCHES MAXIMUM EXPANDED INSIDE DIAMETER: 0.375 INCHES NOMINAL

HT105 3-16BLACK MARKEL CORP.

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-944-7316

RECOVERED WALL THICKNESS: 0.030 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 400.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 0.375 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.187 INCHES MAXIMUM

PVC3-8 TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-939-8941

RECOVERED WALL THICKNESS: 0.030 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 400.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 0.375 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.187 INCHES MAXIMUM

RT-876 3/8BLK TE CONNECTIVITY CORPORATION

CONFIRMED

INSULATION SLEEVING,ELECTRICAL

NSN 5970-00-102-1495

RECOVERED WALL THICKNESS: 0.025 INCHES NOMINAL DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS: 500.0 VOLTS PER MIL /0.001 INCH/ EXPANDED INSIDE DIAMETER: 0.375 INCHES MINIMUM RECOVERED INSIDE DIAMETER: 0.187 INCHES MAXIMUM

Take the family with you

The whole group as CSV — members, makers, stock numbers and order of use.

Export paused

The monthly allowance for this address is used — the pattern reads as catalogue work, not a line to settle.

Whole-catalogue work is what Stage 1(a) is for: every line human-checked against the cited evidence, discrepancies annotated, back inside 24 hours. Free searching stays free — this gate only catches bulk pulls.

Staying inside the regulation — routes from candidate to approved

Codification and qualification say who vouches for a part — they are not installation eligibility. Under EASA Part-21, eligibility flows from the approved design (type design / IPC) or an approved change; under Part-145, acceptance needs an EASA Form 1 or, for genuine standard parts, conformity traceable to the officially recognised standard (145.A.42).

  1. Classify the part. Is it a GENUINE standard part? If the IPC/CMM references only a public specification (AN/MS/NAS/SAE-AS/ISO/EN) with no OEM source-control drawing, buy at source with conformity traceable to that standard.
  2. Check for an approved alternate. The IPC/CMM/vendor list may already carry an alternate part number or vendor code — an already-approved alternate needs no new approval.
  3. Ask the design approval holder. Request the source-control data, written equivalence, or addition of the alternative source to the approved data. Document a refusal.
  4. Raise a design change. Via a Part-21J DOA (or EASA/ADOA): a 21.A.95 minor change adding the alternate to the approved data, backed by an identicality/equivalence file — dimensions, material, class, load rating, lubricant/seal, corrosion protection, acceptance criteria. Critical applications escalate to major change/STC.
  5. FAA-PMA / BASA path. Where the product is also FAA-certificated: PMA parts reach EASA aircraft under the BASA/TIP (non-critical directly; critical via EASA-validated STC).
  6. Production, release, traceability. Approved parts are produced under a POA, released on an EASA Form 1 (marked EPA where applicable), with EN/AS 9120-grade traceability into Part-145/CAMO acceptance.

Stage 1(a): we assemble the equivalence/identicality starter file — the cited evidence this graph holds, shaped for your DOA or compliance department to take forward. See pricing.

Regulatory explainer, not legal advice: paragraph numbers, derogations and the BASA/TIP revision change — verify against the current consolidated Regulation (EU) 748/2012, the EASA Easy Access Rules and the current TIP, and engage your DOA and competent authority early.

Source: DLA Logistics Information Services (FLIS) · cycle 2026-0 · official codification

This crosswalk identifies candidate equivalents with cited evidence. It is not an airworthiness approval. Substitution decisions remain subject to your organisation’s procurement and engineering approval process and the governing maintenance data (AMM/CMM/SRM/CML/OMAT).